Sizing and Selection Tables
How to Select
At Kay Industries we want you to be completely satisfied with your Phasemaster® rotary phase converter. That’s why we work with you to make sure that you get the right phase converter for your application.
To select the best phase converter for your application, follow these steps:
1. Gather Information. A few basic pieces of information are essential to selecting the right phase converter. Fill out the sizing and selection worksheet and you will have all the information needed to ensure your satisfaction.
NOTE: Once you have completed the worksheet, let us handle the rest. Simply submit it to us online, or fax it to us at 574-289-5932. We will contact you within 1 business day with our recommendation.
OR
2. Refer to the Application Guide to choose the right Phasemaster Rotary phase converter model for your application.
3. Pick the proper converter size from our sizing tables.
4. Determine which additional accessories are required for your application, such as weatherproof enclosures, lightning protection and transformers.
If you have any questions, please email us or call us at 574-236-6220, and let one of our application engineering specialists assist you.
How to Use Sizing and Selection Tables
A phase converter carries two ratings. The first and most important rating is the Largest Motor HP that the converter can start. This can be a single motor or a combination of motors. For example, starting one 10 HP motor is the same as starting two 5 HP motors at the same time. A 10 HP converter is the proper size in this case.
The second rating is the Maximum or Total HP that operates simultaneously but does not start together. As a rule, a Type MA Phasemaster® converter can run a total of 3 times as many HP as it can start. A 15 HP, a 10 HP and a 5 HP motor (totaling 30 HP) that start separately but run together could run on a 15HP converter. The largest motor to be started is 15HP and the maximum load does not exceed 45HP.
Never add your total operating HP for sizing purposes unless your loads actually start at exactly the same time. If the total HP operating simultaneously exceeds the Maximum HP capability for that converter, increase converter size to a larger model. Use the largest motor for sizing purposes. Consult Kay Industries to verify your selection.
Never size your converter based on total amperage only – you will probably overpay for that much capacity.
If you have any questions, please email us or call us at 574-236-6220, and let one of our application engineering specialists assist you.
Type MA
Basic converter without controls. The MA requires a field supplied fused disconnect switch for on-off control. It is factory wired for 230 volt operation and field changeable to 460 V.
Model No. |
Largest HP |
Max HP |
Dimensions | |||
L | W | H | Wt. | |||
SD-60 | 1.5 | 3 | 10 | 11 | 12 | 64 |
MA-00 | 2 | 6 | 10 | 12 | 14 | 89 |
MA-0 | 3 | 9 | 11 | 12 | 14 | 108 |
MA-1 | 5 | 15 | 14 | 14 | 17 | 204 |
MA-1B | 7.5 | 22 | 16 | 17 | 20 | 261 |
MA-2 | 10 | 30 | 18 | 17 | 22 | 307 |
MA-3 | 15 | 45 | 20 | 18 | 26 | 419 |
MA-4 | 20 | 60 | 21 | 21 | 28 | 423 |
MA-5 | 25 | 75 | 22 | 21 | 28 | 487 |
MA-6 | 30 | 90 | 23 | 23 | 30 | 622 |
MA-7 | 40 | 120 | 24 | 23 | 30 | 768 |
MA-8 | 50 | 150 | 25 | 27 | 34 | 885 |
MA-9 | 60 | 180 | 27 | 27 | 34 | 923 |
Type MA-A
Includes fuses & starter to switch converter on and off as required by the load. The MA-A can be used on unattended or cyclical loads such as compressors, elevators, or air conditioners.. Specify voltage when ordering
Model No. |
Largest HP |
Max HP |
Dimensions | |||
L | W | H | Wt. | |||
SD-60-A | 1.5 | 3 | 12 | 12 | 14 | 75 |
MA-00-A | 2 | 4 | 12 | 12 | 15 | 100 |
MA-0-A | 3 | 6 | 12 | 12 | 15 | 120 |
MA-1-A | 5 | 10 | 14 | 17 | 18 | 225 |
MA-1B-A | 7.5 | 15 | 17 | 20 | 22 | 277 |
MA-2-A | 10 | 20 | 19 | 20 | 25 | 327 |
MA-3-A | 15 | 30 | 20 | 22 | 26 | 444 |
MA-4-A | 20 | 40 | 22 | 24 | 27 | 450 |
MA-5-A | 25 | 50 | 25 | 24 | 27 | 515 |
MA-6-A | 30 | 60 | 25 | 27 | 33 | 660 |
MA-7-A | 40 | 80 | 26 | 27 | 33 | 805 |
MA-8-A | 50 | 100 | 27 | 29 | 35 | 925 |
MA-9-A | 60 | 120 | 30 | 29 | 35 | 970 |
Type MA-R
Includes factory installed disconnect switch, fuses and terminal blocks in a side-mounted enclosure. Specify operating voltage when ordering.
Model No. |
Largest HP |
Max HP |
Dimensions | |||
L | W | H | Wt. | |||
SD-60-R | 1.5 | 3 | 12 | 12 | 14 | 75 |
MA-00-R | 2 | 4 | 12 | 12 | 15 | 100 |
MA-0-R | 3 | 6 | 12 | 12 | 15 | 120 |
MA-1-R | 5 | 10 | 14 | 17 | 18 | 225 |
MA-1B-R | 7.5 | 15 | 17 | 20 | 22 | 277 |
MA-2-R | 10 | 20 | 19 | 20 | 25 | 327 |
MA-3-R | 15 | 30 | 20 | 22 | 26 | 444 |
MA-4-R | 20 | 40 | 22 | 24 | 27 | 450 |
MA-5-R | 25 | 50 | 25 | 24 | 27 | 515 |
MA-6-R | 30 | 60 | 25 | 27 | 33 | 660 |
MA-7-R | 40 | 80 | 26 | 27 | 33 | 805 |
MA-8-R | 50 | 100 | 27 | 29 | 35 | 925 |
MA-9-R | 60 | 120 | 30 | 29 | 35 | 970 |
Type PI
Totally enclosed converters for pivot irrigation or other severe outdoor duty applications. Also available with auto controls for unattended sites
Model No. |
Largest HP |
Max HP |
Dimensions | |||
L | W | H | Wt. | |||
PI-6 | 2 | 4 | 13 | 16 | 14 | 120 |
PI-10 | 3 | 6 | 14 | 16 | 14 | 136 |
PI-15 | 5 | 10 | 17 | 20 | 14 | 207 |
PI-20 | 7.5 | 15 | 20 | 21 | 20 | 307 |
PI-30 | 10 | 20 | 22 | 21 | 20 | 372 |
PI-40 | 15 | 30 | 25 | 26 | 20 | 503 |
PI-50 | 20 | 40 | 26 | 28 | 21 | 720 |
PI-60 | 25 | 50 | 28 | 28 | 21 | 770 |
PI-80 | 30 | 60 | 31 | 30 | 24 | 905 |
PI-100 | 40 | 80 | 31 | 30 | 24 | 1005 |
PI-120 | 50 | 100 | 33 | 24 | 28 | 1570 |